COMPARE: Single-Use Versus Reusable Catheters for Intermittent Catheterization in Urinary Retention
2026 main report
COMPARE was an assessor-masked, multicenter noninferiority randomized trial comparing reusable uncoated with single-use intermittent catheters in 386 people with urinary retention who catheterized at least twice daily; reusable catheters met the prespecified noninferiority criterion for symptomatic UTI incidence over one year.[1]
- Design and population
- Multicenter, assessor-masked noninferiority randomized trial. Patients aged 16 years or older with neurogenic or nonneurogenic urinary retention who had performed urethral clean intermittent catheterization at least twice daily for at least two weeks.
- Arms
- Reusable uncoated intermittent catheters versus single-use intermittent catheters
- Report and follow-up
- 2026 · One year; modified intention-to-treat mean 11.4 months reusable and 12.0 months single-use
| Endpoint | Results | Effect | Finding |
|---|---|---|---|
| UTIs per patient-month in modified intention-to-treat analysis; absolute incidence-rate difference (reusable minus single-use); noninferiority margin +0.07 UTIs per patient-month | 0.050 (95% CI 0.035 to 0.067) vs 0.054 (95% CI 0.040 to 0.069) | difference -0.004; CI -0.025–0.019 | Met |
| UTIs per patient-month; absolute incidence-rate difference (reusable minus single-use) | 0.052 (n=185) vs 0.054 (n=192) | difference -0.002; CI -0.028–0.026 | Descriptive |
| UTIs per patient-month; absolute incidence-rate difference (reusable minus single-use) | 0.04 (n=113) vs 0.05 (n=177) | difference -0.01; CI -0.032–0.011 | Descriptive |
Harms: Low-grade urethral irritation: 37/185 (20.0%) vs 9/192 (4.7%); UTI-related hospitalization: 3/185 (1.6%) vs 3/192 (1.6%); Macroscopic hematuria: 23/185 vs 24/192
Netherlands Trial Register NL8296 · Report DOI
Design
Dutch outpatient urology clinics enrolled patients aged 16 years or older who had performed clean intermittent catheterization for at least two weeks. Neurogenic and nonneurogenic retention were eligible. Exclusions included nonurethral or temporary catheterization, urethral stricture, urinary tract stones, bladder augmentation, active bladder cancer follow-up, immunosuppression, and impaired comprehension. Participants and research staff knew the allocation; outcome assessors were masked.[1]
The reusable arm used uncoated Cliny catheters for males and PureCath catheters for females. Users rinsed them with tap water before and after catheterization, stored them in 2% sodium hypochlorite renewed daily, and replaced them every two weeks. Single-use catheters were allowed for up to 20% of weekly catheterizations in this arm. The comparison arm continued its usual single-use catheters.[1]
The primary endpoint required acute UTI symptoms plus a positive urine test; culture, sediment, dipslide, or nitrite testing qualified. The prespecified noninferiority margin was +0.07 UTIs per patient-month for the reusable-minus-single-use difference, assessed by the upper limit of a two-sided 95% confidence interval. The primary modified intention-to-treat analysis required completion of a six-week lead-in visit.[1]
Results
In the modified intention-to-treat analysis, symptomatic UTI incidence was 0.050 per patient-month with reusable catheters and 0.054 with single-use catheters. The absolute incidence-rate difference was −0.004 (95% CI −0.025 to 0.019); its upper bound was below the +0.07 margin. At least one UTI occurred in 40/134 (29.9%) versus 59/191 (30.9%), respectively.[1]
Prespecified sensitivity analyses produced differences of −0.002 (95% CI −0.028 to 0.026) in the intention-to-treat population and −0.01 (95% CI −0.032 to 0.011) in the per-protocol population; both upper bounds remained below the prespecified margin. The adherence-adjusted complier-average causal effect estimate was 0.016 (95% CI −0.126 to 0.158) UTIs per patient-month.[1]
At week 52, catheter-related quality of life favored reusable catheters (mean score difference 3.6, 95% CI 0.3 to 7.0), while catheterization satisfaction favored single-use catheters (mean score difference −0.12 for reusable minus single-use, 95% CI −0.22 to −0.01).[1]
Surgery and treatment delivery
Of 193 people randomized to reusable catheters, 185 started treatment and 113 completed one year. Among those who started, 72/185 (39%) discontinued; ease-of-use problems were reported as a discontinuation reason by 39/185 (21.1%), and urethral irritation by 13/185 (7.0%). Reusable catheters accounted for a mean 88.6% of catheterizations in the intention-to-treat population. Of the 113 who completed one year, 105/113 (92.9%) preferred to continue using the reusable device.[1]
Adverse events
Low-grade urethral irritation occurred in 37/185 (20.0%) reusable users versus 9/192 (4.7%) single-use users. UTI-related hospitalization occurred in 3/185 (1.6%) and 3/192 (1.6%), respectively. Macroscopic hematuria was reported in 23/185 and 24/192, and urethral stricture in one participant in each group.[1]
Limitations
The six-week lead-in excluded many early discontinuers from the primary analysis, particularly in the reusable arm. The noninferiority margin of +0.07 UTIs per patient-month exceeded the observed single-use incidence of 0.054; the adherence-adjusted estimate had a wide interval spanning that margin. Participants and research staff were unblinded, and the UTI definition permitted positive urine tests other than culture. The findings reflect the tested uncoated devices and their daily hypochlorite cleaning regimen.[1]
In conversation
Same setting Cardenas hydrophilic-catheter SCI trial (2011)
Report history
| Published | Report | Cutoff | Headline results | Citation |
|---|---|---|---|---|
| 2026-06-01 | One-year primary report · primary | — | UTIs per patient-month in modified intention-to-treat analysis; absolute incidence-rate difference (reusable minus single-use); noninferiority margin +0.07 UTIs per patient-month: 0.050 (95% CI 0.035 to 0.067) vs 0.054 (95% CI 0.040 to 0.069); difference -0.004; CI -0.025–0.019 Met Patients with at least one UTI during modified intention-to-treat follow-up: 40/134 (29.9%) vs 59/191 (30.9%); — UTIs per patient-month; absolute incidence-rate difference (reusable minus single-use): 0.052 (n=185) vs 0.054 (n=192); difference -0.002; CI -0.028–0.026 Descriptive UTIs per patient-month; absolute incidence-rate difference (reusable minus single-use): 0.04 (n=113) vs 0.05 (n=177); difference -0.01; CI -0.032–0.011 Descriptive Estimated absolute difference in UTIs per patient-month accounting for reusable-catheter nonadherence: Reusable adherence modeled vs Single-use assignment; difference 0.016; CI -0.126–0.158; P 0.83 Intermittent Self-Catheterization Questionnaire score at week 52; mean difference (reusable minus single-use): Higher vs Lower; difference 3.6; CI 0.3–7; P 0.03 Intermittent Catheterization Satisfaction Questionnaire score at week 52; mean difference (reusable minus single-use): Lower vs Higher; difference -0.12; CI -0.22–-0.01; P 0.03 | van Veen FEE, Christiaans CHH, Berendsen SA, et al. Single-Use vs Reusable Catheters for Intermittent Catheterization in Patients With Urinary Retention: The COMPARE Randomized Clinical Trial. *JAMA Netw Open.* 2026;9(6):e2620871. doi:10.1001/jamanetworkopen.2026.20871 DOI |
References
1. van Veen FEE, Christiaans CHH, Berendsen SA, et al. "Single-Use vs Reusable Catheters for Intermittent Catheterization in Patients With Urinary Retention: The COMPARE Randomized Clinical Trial." JAMA Netw Open. 2026;9(6):e2620871. doi:10.1001/jamanetworkopen.2026.20871